{"id":2960,"date":"2024-10-24T12:44:28","date_gmt":"2024-10-24T12:44:28","guid":{"rendered":"https:\/\/iceag.com\/referenzen\/tad-fug-muellheizkraftwerk-ulm-donautal\/"},"modified":"2025-02-07T14:49:29","modified_gmt":"2025-02-07T14:49:29","slug":"tad-fug-muellheizkraftwerk-ulm-donautal","status":"publish","type":"reference","link":"https:\/\/iceag.com\/en\/referenzen\/tad-fug-muellheizkraftwerk-ulm-donautal\/","title":{"rendered":"TAD + FUG, M&uuml;llheizkraftwerk Ulm-Donautal"},"content":{"rendered":"\n<section class=\"eoss_hero_small alignfull\"><div class=\"eoss_hero_small_content\"><h4 class=\"eoss_hero_small_content_subtitle\">Ulm, Germany<\/h4><h1 class=\"eoss_hero_small_content_title\"><br>TAD + FUG, M&uuml;llheizkraftwerk Ulm-Donautal<\/h1><div class=\"eoss_hero_small_content_text\"><strong>Client:<\/strong> TAD, Zweckverband Thermische Abfallverwertung Donautal<br><strong>Operator:<\/strong> FUG, Fernw&auml;rme Ulm GmbH<br><strong>Location: <\/strong>Ulm, Germany<br><strong>Capacity:<\/strong> 2x 80&apos;000 t\/a<br><strong>Duration:<\/strong> 1997 &ndash; 2023<br><strong>Project volume:<\/strong> Existing plant: EUR 29 million New 3rd  line: approx. 70 million EUR<br><br><strong>PDF:<\/strong> <a href=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Referenzblatt-MHKW-Ulm-DE-2023.pdf\" data-type=\"attachment\" data-id=\"1582\" target=\"_blank\" rel=\"noreferrer noopener\">TAD + FUG, M&uuml;llheizkraftwerk Ulm-Donautal<\/a><\/div><\/div><figure class=\"eoss_background eoss_hero_small_bg\"><img decoding=\"async\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/Referenzblatt-MHKW-Ulm-DE-2023.jpg\"\/><\/figure><\/section>\n\n<div class=\"wp-block-eoss-ananas-blocks-background-white alignfull\"><div>\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-cf05694f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Plant description<\/h2>\n\n\n\n<p>The Ulm-Donautal waste-to-energy plant (MHKW) was commissioned in 1997. I.C.E. already took over various execution tasks on the construction site during the construction of the new building. This good cooperation continues to this day.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"488\" height=\"366\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/Referenzblatt-MHKW-Ulm-DE-2023-1.jpg\" alt=\"\" class=\"wp-image-2092\" style=\"aspect-ratio:3\/2;object-fit:cover;width:650px\" srcset=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/Referenzblatt-MHKW-Ulm-DE-2023-1.jpg 488w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/Referenzblatt-MHKW-Ulm-DE-2023-1-300x225.jpg 300w\" sizes=\"auto, (max-width: 488px) 100vw, 488px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-cf05694f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"490\" height=\"241\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/Referenzblatt-MHKW-Ulm-DE-2023-2.jpg\" alt=\"\" class=\"wp-image-2095\" style=\"aspect-ratio:3\/2;object-fit:cover;width:650px\" srcset=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/Referenzblatt-MHKW-Ulm-DE-2023-2.jpg 490w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/Referenzblatt-MHKW-Ulm-DE-2023-2-300x148.jpg 300w\" sizes=\"auto, (max-width: 490px) 100vw, 490px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Technology<\/h2>\n\n\n\n<p><strong>Waste:<\/strong> <br\/>Household and commercial waste<\/p>\n\n\n\n<p><strong>Existing plant (2 lines):<\/strong><br\/>Grate firing<br\/>Steam boiler with SNCR<br\/>Electric filter<br\/>Gas\/gas heat exchanger<br\/>3-stage wet scrubber<br\/>Additive injection<br\/>Fabric filter with steam\/gas preheater<br\/>Waste water treatment<br\/>Evaporation plant<br\/>Extraction condensation turbine<\/p>\n\n\n\n<p><strong>Heat utilisation:<\/strong> <br\/>Electricity, district heating<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-eoss-ananas-blocks-background-grey alignfull\"><div>\n<div style=\"height:75px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Services<\/h2>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Strategic planning<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Condition assessment<\/li>\n\n\n\n<li>Maintenance, capacity and future planning<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Preliminary planning<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Replacement of slag storage and treatment plant<\/li>\n\n\n\n<li>Performance increase of L1+2 Optimisation of the energy efficiency of the overall plant<\/li>\n\n\n\n<li>Optimisation of ammonia injection (SNCR)<\/li>\n\n\n\n<li>Optimisation of air preheating<\/li>\n\n\n\n<li>Enlargement of waste bunker 3. Process line<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Design planning \/ approval planning \/ execution planning \/ preparation and<br\/>involvement in the award of contracts \/<br\/>property monitoring<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Increased performance of the entire plant<\/li>\n\n\n\n<li>Modernisation of furnace and boiler<\/li>\n\n\n\n<li>Optimisation of heat transfer RGR L1+2<\/li>\n\n\n\n<li>Renewal of seepage water storage<\/li>\n\n\n\n<li>Conversion of grate ash removal<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Design planning \/ execution planning<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Renovation \/ replacement of induced-draft fans L1+2<\/li>\n\n\n\n<li>Renovation and increased performance of fabric filter L1+2<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Design planning<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Enlargement and renovation of waste bunker<\/li>\n\n\n\n<li>Partial renovation of EMSR technology<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Approval planning<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Various BImSchG (Federal Immission Control Act) change notifications \/ approval notifications for optimisation of overall plant systems<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Property monitoring and documentation<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Evaluation measurements of the above projects<\/li>\n\n\n\n<li>Documentation review<\/li>\n\n\n\n<li>Support during the warranty period<\/li>\n\n\n\n<li>Maintenance planning<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group alignfull has-secondary-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0\">\n<div class=\"wp-block-group is-content-justification-space-between is-nowrap is-layout-flex wp-container-core-group-is-layout-cb46ffcb wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading\">We value quality!<\/h4>\n\n\n\n<h2 class=\"wp-block-heading has-background-color has-text-color has-link-color wp-elements-de65a7945160a4b50ed7c78736f25512\">We are audited and fulfil all the requirements<br\/>of the international ISO 9001 and 45001 standards.<\/h2>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"582\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2023\/10\/siegel_9001_45001_2.jpg\" alt=\"\" class=\"wp-image-1956\" style=\"object-fit:cover;width:284px;height:auto\" srcset=\"https:\/\/iceag.com\/wp-content\/uploads\/2023\/10\/siegel_9001_45001_2.jpg 1920w, https:\/\/iceag.com\/wp-content\/uploads\/2023\/10\/siegel_9001_45001_2-300x91.jpg 300w, https:\/\/iceag.com\/wp-content\/uploads\/2023\/10\/siegel_9001_45001_2-1024x310.jpg 1024w, https:\/\/iceag.com\/wp-content\/uploads\/2023\/10\/siegel_9001_45001_2-768x233.jpg 768w, https:\/\/iceag.com\/wp-content\/uploads\/2023\/10\/siegel_9001_45001_2-1536x466.jpg 1536w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/figure>\n<\/div>\n<\/div>\n","protected":false},"author":3,"featured_media":2099,"template":"","reference_type":[],"class_list":["post-2960","reference","type-reference","status-publish","has-post-thumbnail","hentry"],"acf":[],"featured_media_url":"https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/Referenzblatt-MHKW-Ulm-DE-2023.jpg","acf_values":{"ort":"Ulm, Germany"},"_links":{"self":[{"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/reference\/2960","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/reference"}],"about":[{"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/types\/reference"}],"author":[{"embeddable":true,"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/users\/3"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/media\/2099"}],"wp:attachment":[{"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/media?parent=2960"}],"wp:term":[{"taxonomy":"reference_type","embeddable":true,"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/reference_type?post=2960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}