{"id":2370,"date":"2024-04-22T14:49:26","date_gmt":"2024-04-22T14:49:26","guid":{"rendered":"https:\/\/iceag.com\/boiler-technology\/"},"modified":"2025-03-25T15:09:31","modified_gmt":"2025-03-25T15:09:31","slug":"boiler-technology","status":"publish","type":"page","link":"https:\/\/iceag.com\/en\/range-of-services\/boiler-technology\/","title":{"rendered":"Boiler technology"},"content":{"rendered":"\n<section class=\"eoss_hero_small alignfull\"><div class=\"eoss_hero_small_content\"><h4 class=\"eoss_hero_small_content_subtitle\">Everything from one source<\/h4><h1 class=\"eoss_hero_small_content_title\">Boiler technology<\/h1><div class=\"eoss_hero_small_content_text\"><\/div><\/div><figure class=\"eoss_background eoss_hero_small_bg\"><img decoding=\"async\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Vorschlag-5.jpg\"\/><\/figure><\/section>\r\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<p>Our modernisation services in the area of waste incineration are aimed at bringing your installations up to date and making them more efficient.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"297\" height=\"296\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/029_012204_ICE_Ueberarbeitung_Firmenpraesentation_Powerpoint_Vorlage_Icons_4.png\" alt=\"\" class=\"wp-image-1156\" style=\"width:353px;height:auto\" srcset=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/029_012204_ICE_Ueberarbeitung_Firmenpraesentation_Powerpoint_Vorlage_Icons_4.png 297w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/029_012204_ICE_Ueberarbeitung_Firmenpraesentation_Powerpoint_Vorlage_Icons_4-150x150.png 150w\" sizes=\"auto, (max-width: 297px) 100vw, 297px\" \/><\/figure>\n<\/div>\n<\/div>\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-group alignfull has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"background-color:#585858;margin-top:0;margin-bottom:0\">\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-content-justification-space-between is-nowrap is-layout-flex wp-container-core-group-is-layout-c073264b wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full is-resized is-style-rounded\"><img loading=\"lazy\" decoding=\"async\" width=\"532\" height=\"400\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/ice-ambros-gehr.jpg\" alt=\"\" class=\"wp-image-2231\" style=\"aspect-ratio:1;object-fit:cover;width:250px\" srcset=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/ice-ambros-gehr.jpg 532w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/ice-ambros-gehr-300x226.jpg 300w\" sizes=\"auto, (max-width: 532px) 100vw, 532px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-fe9cc265 wp-block-group-is-layout-flex\">\n<h2 class=\"wp-block-heading has-background-color has-text-color has-link-color wp-elements-26f29db99fb83d9d46dc59daf72d98cb\">\u201cBoiler technology from a single source; from planning and production to installation in your plant.\u201d<\/h2>\n\n\n\n<p class=\"has-background-color has-text-color has-link-color wp-elements-7751afa0bdc294489de9d6daf688c155\"><em>Ambros Gehr, Head of Boiler Technology<\/em><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\"><\/div>\n<\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n<div class=\"wp-block-eoss-ananas-blocks-background-white alignfull\"><div>\n<div style=\"height:100px;width:0px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns has-medium-font-size is-layout-flex wp-container-core-columns-is-layout-55c989da wp-block-columns-is-layout-flex\" style=\"margin-top:0;margin-bottom:0;padding-right:0;padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Boiler inspections<\/h2>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>We offer comprehensive boiler inspections based on our long-standing experience in this area. If necessary, we receive support from other experts from our subsidiary, Dampfkesselbau W.A.M.S.E.R. GmbH. The findings from the inspection can then be used to suggest renovation and conversion measures and to prepare a maintenance and renovation plan. This gives you the certainty that the necessary measures will be taken at the right time to ensure the smooth operation of your plant.\u00a0 In addition, the other components, e.g. grate, refractory lining, thermal installations, flue gas purification, etc., can also be inspected to enable a comprehensive assessment of the condition of the entire plant.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Kessel_Werterhaltung-1024x768.jpg\" alt=\"\" class=\"wp-image-1528\" style=\"aspect-ratio:4\/3;object-fit:cover\" srcset=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Kessel_Werterhaltung-1024x768.jpg 1024w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Kessel_Werterhaltung-300x225.jpg 300w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Kessel_Werterhaltung-768x576.jpg 768w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Kessel_Werterhaltung.jpg 1488w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"margin-top:var(--wp--preset--spacing--50);margin-bottom:var(--wp--preset--spacing--50);height:81px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-medium-font-size is-layout-flex wp-container-core-columns-is-layout-55c989da wp-block-columns-is-layout-flex\" style=\"margin-top:0;margin-bottom:0;padding-right:0;padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"927\" height=\"618\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/iStock-1390307383.jpg\" alt=\"\" class=\"wp-image-2199\" style=\"aspect-ratio:4\/3;object-fit:cover\" srcset=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/iStock-1390307383.jpg 927w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/iStock-1390307383-300x200.jpg 300w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/10\/iStock-1390307383-768x512.jpg 768w\" sizes=\"auto, (max-width: 927px) 100vw, 927px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Boiler studies, natural circulation calculations and WDK calculations<\/h2>\n\n\n\n<p>We have the necessary software to carry out thermal boiler calculations, including natural circulation calculations. This enables the optimisation of existing steam boilers or the identification of any weak points and the development of potential modifications to eliminate them. These can then be planned in detail, produced and installed together with our subsidiary or a partner company.<\/p>\n\n\n\n<p>The licensed software is used by many boiler manufacturers and thus provides the bridgehead for any subsequent production.<\/p>\n\n\n\n<p>With our software and our own tools, we can not only model your steam boiler, but also simulate the entire water-steam circulation system. Based on the results of these calculations, measures to increase the efficiency of your system can be evaluated and implemented.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"margin-top:var(--wp--preset--spacing--50);margin-bottom:var(--wp--preset--spacing--50);height:81px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-medium-font-size is-layout-flex wp-container-core-columns-is-layout-cf05694f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Repairs and conversions<\/h2>\n\n\n\n<p>We are also there for you for the implementation of repair or conversion measures. Our experienced assembly and revision managers perform this work in co-operation with W.A.M.S.E.R. GmbH or third-party companies to make older boiler systems fit and efficient again.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1440\" height=\"1080\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Bermuda-2-Personen_K-edited-2.jpg\" alt=\"\" class=\"wp-image-1519\" style=\"aspect-ratio:4\/3;object-fit:cover\" srcset=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Bermuda-2-Personen_K-edited-2.jpg 1440w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Bermuda-2-Personen_K-edited-2-300x225.jpg 300w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Bermuda-2-Personen_K-edited-2-1024x768.jpg 1024w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Bermuda-2-Personen_K-edited-2-768x576.jpg 768w\" sizes=\"auto, (max-width: 1440px) 100vw, 1440px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"margin-top:var(--wp--preset--spacing--50);margin-bottom:var(--wp--preset--spacing--50);height:81px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-medium-font-size is-layout-flex wp-container-core-columns-is-layout-cf05694f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1152\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Kessel-VfA-Buchs-OL2-2020_DSC05641_Ausschnitt-rotated.jpg\" alt=\"\" class=\"wp-image-1524\" style=\"aspect-ratio:3\/2;object-fit:cover\" srcset=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Kessel-VfA-Buchs-OL2-2020_DSC05641_Ausschnitt-rotated.jpg 1536w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Kessel-VfA-Buchs-OL2-2020_DSC05641_Ausschnitt-300x225.jpg 300w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Kessel-VfA-Buchs-OL2-2020_DSC05641_Ausschnitt-1024x768.jpg 1024w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Kessel-VfA-Buchs-OL2-2020_DSC05641_Ausschnitt-768x576.jpg 768w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Delivery of boiler components<\/h2>\n\n\n\n<p>The I.C.E. AG subsidiary, Dampfkesselbau W.A.M.S.E.R. GmbH, undertakes the production of boiler components in the factory as well as the on-site assembly and coating work. The company has its own production facility where all boiler components such as membrane walls including bends, collectors, heat exchangers, pipework or rapping units can be manufactured. Further information about our subsidiary is available at: <a href=\"https:\/\/dkb-wamser.de\" target=\"_blank\" rel=\"noreferrer noopener\">dkb-wamser.de<\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/dkb-wamser.de\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"307\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Logo-WAMSER-1024x307.jpg\" alt=\"\" class=\"wp-image-1557\" style=\"width:289px\" srcset=\"https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Logo-WAMSER-1024x307.jpg 1024w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Logo-WAMSER-300x90.jpg 300w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Logo-WAMSER-768x230.jpg 768w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Logo-WAMSER-1536x461.jpg 1536w, https:\/\/iceag.com\/wp-content\/uploads\/2024\/07\/Logo-WAMSER.jpg 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group alignfull has-primary-background-color has-background is-layout-constrained wp-container-core-group-is-layout-be04af43 wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0\">\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-content-justification-space-between is-nowrap is-layout-flex wp-container-core-group-is-layout-c073264b wp-block-group-is-layout-flex\">\n<h2 class=\"wp-block-heading has-background-color has-text-color has-link-color wp-elements-2b04051bfc8d6b99b45c46336469ad11\">Contact us<\/h2>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-ice-button-two\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iceag.com\/en\/contact-us\/\">Contact us now without obligation<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n<div class=\"wp-block-group alignfull has-secondary-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0\">\n<div class=\"wp-block-group is-content-justification-space-between is-nowrap is-layout-flex wp-container-core-group-is-layout-cb46ffcb wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading\">We value quality!<\/h4>\n\n\n\n<h2 class=\"wp-block-heading has-background-color has-text-color has-link-color wp-elements-de65a7945160a4b50ed7c78736f25512\">We are audited and fulfil all the requirements<br\/>of the international ISO 9001 and 45001 standards.<\/h2>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"582\" src=\"https:\/\/iceag.com\/wp-content\/uploads\/2023\/10\/siegel_9001_45001_2.jpg\" alt=\"\" class=\"wp-image-1956\" style=\"object-fit:cover;width:284px;height:auto\" srcset=\"https:\/\/iceag.com\/wp-content\/uploads\/2023\/10\/siegel_9001_45001_2.jpg 1920w, https:\/\/iceag.com\/wp-content\/uploads\/2023\/10\/siegel_9001_45001_2-300x91.jpg 300w, https:\/\/iceag.com\/wp-content\/uploads\/2023\/10\/siegel_9001_45001_2-1024x310.jpg 1024w, https:\/\/iceag.com\/wp-content\/uploads\/2023\/10\/siegel_9001_45001_2-768x233.jpg 768w, https:\/\/iceag.com\/wp-content\/uploads\/2023\/10\/siegel_9001_45001_2-1536x466.jpg 1536w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>We supply everything from a single source, from condition assessment to the finished repair<\/p>\n","protected":false},"author":3,"featured_media":995,"parent":2393,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-2370","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/pages\/2370","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/comments?post=2370"}],"version-history":[{"count":12,"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/pages\/2370\/revisions"}],"predecessor-version":[{"id":3637,"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/pages\/2370\/revisions\/3637"}],"up":[{"embeddable":true,"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/pages\/2393"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/media\/995"}],"wp:attachment":[{"href":"https:\/\/iceag.com\/en\/wp-json\/wp\/v2\/media?parent=2370"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}